One often averages many measurements in order to cancel out errors. A lot of the noise in my shop comes from 60Hz power-line hum so to make measurements I average over 1/60th of a second, one complete cycle of the interfering noise. With my recent SensorServer conversion I started applying this technique everywhere which lead to a surprising result on one particular channel:
Uploaded image
This shows my power-line waveform monitoring channel: All noise by this definition. Notice that it drops to near zero (peak-to-peek) on Sept 20. That's when my sensor network conversion happened (time here is reported in GMT.) I noticed the change a day later, wondered why it didn't drop all the way to zero, and started investigating.
I had been taking samples, 100 at a time, with the Txtzyme code "100{4sp150u}". This says, sample and print channel 4, wait 150usec, repeat. The timing is approximate here, because the other instructions take microseconds too. I ball-parked these numbers when dealing with my first hum problem. Maybe I can do better.
I wrote a command line script to sweep through various repeat counts, thereby varying slightly the period over which I observed the hum. I figured one of these values would be close to the desired 1/60 second. I'd know I had found the ideal number when the peak-to-peak value was the smallest. Here's what I found:
Uploaded image
This shows that collecting 107 samples more correctly averages over the desired interval. It also tells me how fast Txtzyme runs by measuring it against the ac power as a timebase. If 107 iterations equals 1/60 second, then one iteration equals 155.8 microseconds. That means my loop overhead is 5.8 microseconds. Not bad.
I changed the loop count in my acquisition logic the next day and this shows in the first graph as a peak-to-peak amplitude of darn near zero. Cool, eh?
Comments
Yes, yes, I know I could avoid hum by building my circuits in properly shielded boxes. But I find that, er, confining. My approach to sensors has been to extract information from dirty signals rather than striving for clean ones. — WardCunningham
Usually a low source impedance matters much more than shielding. Often it's just a matter of using lower value resistors or an opamp, though all sorts of tricky noise issues come into play once you start adding amplifiers. It's also possible to add a small value capacitor directly at the pin to ground... assuming the signal isn't from an opamp that would become unstable when driving a capacitive load. A tiny capacitor lowers the source impedance at high frequency, which is what matter when the A/D "samples" your signal onto its internal capacitor. — paul
I think I showed off my analog temp sensor on a Teensy at the last meeting, and lamented that the readings were really noisy (+/- 3-4LSB most of the time, but occasional +/- 20-30LSB popping up every few seconds). I'll have to try different sampling frequencies and averaging methods; maybe I'm getting some 60Hz noise in there somehow. — spacewrench
My graph suggests that the "ideal" repeat count would be between 106 and 107. I repeated my experiment, this time sweeping between 1060 and 1070 (integrating 10 cycles, not just one) and found 1066 gave me the best result: +/- one-quarter LSB. — WardCunningham
I modified my SensorServer logging of this particular channel to average over 20 cycles. This further reduces the 60Hz signal because I can more accurately specify whole cycles when I use larger counts.
Uploaded image
What I don't understand is why the mean value would shift as it clearly has in this picture:
My sampling is not synchronized in any way that I understand so I can't explain why it would favor noise in the positive direction over the negative. — WardCunningham
Uploaded image
I'm only now getting around to my original purpose for this sensor: observing the waveform distortion (flat-topping) caused by the spread of switching power supplies. Here is the signal Txtzyme Remote sees for my AC line: Notice that the peak of this signal is not particularly graceful as we would expect from the sine function. I quantify this distortion using the crest factor, the amount that a peak voltage measurement differs from a True RMS measurement. I compute it as follows:
avg = result.inject() {|s, e| s + e} / result.length rms = Math.sqrt(result.inject() {|s, e| s + (e - avg)**2} / result.length) crest = (result.max - avg) / rms crest / Math.sqrt(2)
For a pure sinusoid, the crest factor is 1.414. The last step here converts the computed value to a percentage of the ideal where anything less than unity would indicate flat-topping.
I'm now logging this and will alert you all should our grid's wave shape deteriorate unexpectedly. Right now, at my house, it is running around 97% of ideal. — WardCunningham